Công ty TNHH công nghệ số Tân Thành

Mạch điều khiển van tỷ lệ proportional valve amplifier board, PF-DC-10,PF-DC-24

  • Đăng ngày 09-06-2020 02:46:38 PM - 385 Lượt xem
  • Mã sản phẩm: PF-DC-10,PF-DC-24
  • Mạch điều khiển van tỷ lệ proportional valve amplifier board, PF-DC-10,PF-DC-24

    Tình trạng sản phẩm:


    Quanzhou Dongchi Electronic Technology Co., Ltd

    Product name Power amplifier for flow pressure control valve
     
    Model PF-DC-10
     
    The main technical parameters:
    Power supply: DC (direct current) 24/48V
    Maximum output power: 24/48W
    Maximum output current: 1050MA
    Response speed: 0.2-5s
    Load impedance: 10/40 ohms (when the load is 40 ohms,
    The input voltage can only be 48V, and can only be connected between F(DC+) and GND)
    Control signal input: 0~10VDC
    FUSE: 3A/250V
    Flutter frequency: 0-500HZ
    Ambient temperature: 0~65℃
    Temperature drift (maximum): 0.3mA/C
     
    Applicable control type
    Control all direct-acting and pilot-operated, overflow-type proportional pressure flow valves without electrical position feedback.
    With a ramp generator, the rise and fall times can be adjusted separately, and the current limit/
    Lower limit setting. Power supply wrong pole protection function. The products are all made by SMD patch technology, small size
    Strong interference, good quality and low price.
     
    English description of terminal
    P(DC+) ─ Pressure input power DC24V
    F(DC+) ─ Flow input power DC24V or DC48V
    P=pressure GND - input power common
    F=flow P+-positive pressure valve
    DC=DC P- ─ negative pressure valve
    F+ ─Flow valve positive
    F- ─Flow valve negative
    12V ─ auxiliary power supply for variable resistance
    GND-control common point
    P(vin) ─ Pressure input signal point
    F(vin) ─ Flow input signal point
     
    Definition of potentiometer on circuit board P(MAX) ─ Maximum pressure adjustment
    P(MIN)-minimum pressure adjustment (adjusted at the factory, no need to adjust)
    P(UP) ─ Pressure ramp-up time (factory adjusted to the minimum value)
    P(DOWN)─Pressure ramp down time (factory adjusted to minimum value)
    F(UP) ─ Flow ramp-up time (factory adjusted to minimum value)
    F(DOWN)─Flow ramp down time (factory adjusted to the minimum value)
    F(MAX) ─ Maximum flow adjustment
    F(MIN) ─ The adjustment of the minimum flow rate (the factory has been adjusted, no need to adjust)

     

    Full name  Power amplifier for flow pressure control valve
    English Translation Power Amplifiers For Pressure & Flow Control Valves
       
    model PF-DC-24
       
    parameter Power supply: DC (direct current) 24/48V
      Maximum output power: 24/48W 
      Maximum output current: 1050MA               
      Response speed: 0.2-5s
      Load impedance: 10/40 ohms  (when the load is 40 ohms, the input voltage can only be 48V, and it can only be connected between F(DC+) and GND)
      Control signal input: 0~10VDC 
      FUSE: 3A/250V
      Flutter frequency: 0-500HZ
      Ambient temperature: 0~65℃ 
      Temperature drift (maximum): 0.3mA/C
       
    Applicable control Control all direct-acting and pilot-operated, overflow-type proportional pressure flow valves without electrical position feedback. It has a ramp generator, which can separately adjust the rise and fall time, and can also set the upper/lower current limit. The power supply has wrong pole protection function. The products are all made by SMD patch technology, small size, strong anti-interference, good quality and low price.
       
    English description of terminal P(DC+)        ─Pressure      input power DC24V 
      F(DC+)      ─      Flow input power DC24V or DC48V 
    P=pressure GND           -      input power common
    F=Flow P+ ─Pressure valve positive
    DC=DC P- ─ negative pressure valve 
      F+ ─Flow valve positive
      F- ─Flow valve negative
      12V    ─ auxiliary power supply for variable resistance
      GND-control common point
      P(vin)    ─ Pressure input signal point
      F(vin)    ─ Flow input signal point
       
    Definition of potentiometer on circuit board P(MAX) ─ Maximum pressure adjustment
      P(MIN)-minimum pressure adjustment     ( adjusted at the factory, no need to adjust)
      P(UP) ─ Pressure ramp-up time  (factory adjusted to the minimum value)
      P(DOWN)─Pressure ramp down time   (factory adjusted to minimum value)
      F(UP) ─ Flow ramp-up time  (factory adjusted to minimum value)
      F(DOWN)─Flow ramp down time   (factory adjusted to the minimum value)
      F(MAX) ─ Maximum flow adjustment
      F(MIN) ─ The adjustment of the minimum flow rate     (the factory has been adjusted, no need to adjust)



         

     



    TÂN THÀNH CAM KẾT

    • Sản phẩm, hàng hóa chính hãng.
    • Giá cả cạnh tranh.
    • Dịch vụ chăm sóc khách hàng tận tâm.

    Thông Tin Công Ty

    Đã thông báo

     


    THÔNG TIN LIÊN HỆ:
    -------------------------------
    CÔNG TY TNHH THIẾT BỊ CÔNG NGHIỆP TTH
    Trụ sở: số 124 ngõ 79 Yên Hoà-Cầu giấy-HN
    Kinh doanh 1 : 0816.861.515
    Kinh doanh 2 : 0836.861.515
    Kinh doanh 3 : 0926.511.515
    Kinh doanh 4 : 0916.861.515
    Kinh doanh 5 : 0888.868.515
    Kinh doanh 6 : 0917.971.515
    Website: http://tanthanh-automation.com
    Website: http://thietbitudongtanthanh.com
    Website: http://diencongnghieptanthanh.com
    Email: tthkinhdoanh@gmail.com
    Email: tthkinhdoanh01@gmail.com

  • Kết nối với chúng tôi